If your email program is having difficulty displaying this email, click here.  

Veterans Affairs Newsletter
1st Quarter, FY2017

Dragon Medical Network Edition 

Financial Health for the VA...Quality Care for America's Veterans.


In This Issue...

Support Tips
Contact Us

VA Support Trends
CPRS Focus
Recommended iSupport KBs


Support Tips


Initiate Remote Session into VA Workstation using Microsoft Lync

The iSupport solution below outlines how to initiate a remote troubleshooting session to a VA workstation using Microsoft Lync.

Due to security restrictions many remote access programs cannot be used on the VA network. However, Microsoft Lync can be used to gain remote access to VA workstations.

NSD personnel and VALDAs (VA Local Dragon Administrators) are approved to provide technical support and will require this ability to remotely access VA workstations.

 

To learn more and to keep current with any changes to this topic, log in to iSupport and click the solution link below:

16790: Steps to initiate remote session into VA workstation using Microsoft Lync


 

DMNE Trend Usage Reports Explained...

In Dragon Medical Network Edition (DMNE), version 2.x, the DMNE client sends speech usage metrics to the Nuance Management Server (NMS). A Nuance Management Console (NMC) administrator can design and run queries to report on speech metrics for DMNE version 2.x users under Trends > Speech Trends > Speech Usage. The following reporting criteria can be configured:

  • Organization Name
  • Last / First Name
  • Start / End Date and Time
  • Site, Group
  • Group by (first/second): Site/Group/User
  • Display results in a grid format by: Hour/Day/Week/Month
  • Display results in a graph format by: Words/Minutes/Characters

Below are some expected characteristics for DMNE reporting produced through the NMC.


Words and Characters Tracked

From the NMC, under Trends > Speech Trends, the output for the DMNE Speech Usage report includes two (2) columns "Total Words" and "Total Characters" that track only spoken words recognized by the Dragon speech engine. This encompasses only dictation and spoken command names. This parallels what is presented in the DMNE client's Recognition History. The following criteria is not tracked for speech usage reporting:

  • Rejected speech utterances
  • Spaces
  • Typed text
  • Transferred text
  • Text resulting from output of executing a command (Text and Graphics command)
  • Corrected text
  • Deleted text

License Usage Report

From the NMC, under Trends > Usage, the output for the DMNE License Usage report will not show an individual's number of logins over the time specified.

For example, reporting will not show that Dr. Smith logged in five (5) times last week. However, it will show the total accumulated login count for Dr. Smith over the life of the account if Dr. Smith logged in during the time specified. If Dr. Smith did not login during the specified time frame then the report will show "0". The report merely looks at the time specified, then checks that against the last login date. If the last login date is within the specified date range of the report, then the report will display the available totals.

The Device Usage report works in the same fashion except with hostnames.

Examples:

Date Range: 5/1/2016-5/3/2016
Last Login date: 4/29/2016
Result: Does not display cumulative total count

Date Range: 5/1/2016-5/3/2016
Last Login date: 5/2/2016
Result: Displays cumulative total count

 

To learn more and to keep current with any changes to this topic, log in to iSupport and click the solution links below:

17081: DMNE License and Device Usage reports explained

16375: Criteria used for Dragon Medical Network Edition reporting metrics


 

   back to top

 


Contact Us


We're Listening!

As a speech recognition company serving our customers, Nuance places a premium on listening.

Please use the resources below to contact us.

 

iSupport Portal
Product Enhancement / Suggestion
Contacts at nuance.com

Newsletter Feedback

Newsletter Unsubscribe


 

   back to top

 


VA Support Trends


Troubleshooting Profile Corruption

If a Dragon Medical user is unable to open their user profile, the first step if to identify any error message that accompanies this failure. There are several categories of causes for the inability of Dragon Medical to open a user profile:

  • Internal Profile Corruption
  • Windows Folder Permissions
  • Profiles Cannot Be Accessed
  • Locked Profiles and Breaking the Lock
  • Missing PowerMic Dictation Source
  • Unable to add Mic-In Dictation Source

Specific errors associated with each of these general categories as well as steps to resolve these errors can be found in iSupport solution:

16453 - Troubleshooting Profile Corruption Errors


 

   back to top

 


CPRS Focus


Jumping Cursor within CPRS

Customers using Dragon Medical Network Edition (DMNE) and Computerized Patient Record System CPRS may experience jumping cursor issues.

The VA is currently using different versions of CPRS. The two main versions currently in use are CPRS 30a as well as CPRS 30b. There is a compatibility issue between DMNE and CPRS 30a that can cause a jumping cursor and full text control issues within the CPRS application.


Resolution

If the provider is using CPRS 30a, the Dragon Medical Dictation Box is the only workaround.

Otherwise, users will need to install CPRS 30b
(Software Patch and version number: OR*3*350).


Note NOTE: CPRS software installation is controlled by OIT and not Nuance.


Once CPRS 30b is installed, the Dragon nsapps.ini file can be edited to provide full text control as well as resolve the jumping cursor issue. This fix works for both DMEE as well as DMNE within CPRS 30b . The .ini file edit below is based on the CPRS executable name. There have been two different exe names in use, and as such, both edits are displayed below. The CPRS executable name should be verified if the provider is reporting issues while using CPRS 30b to ensure the proper ini edit was made.

File location:
C:\ProgramData\Nuance\NaturallySpeaking12
\nsapps.ini


CPRS.exe

If CPRS executable name is CPRS.exe, add the following four (4) lines at the at the bottom of the file:

[CPRS]
App Support GUID={dd100104-6205-11cf-ae61-0000e8a28647}
[CPRS\Enable Class Names]
TRichEdit=4 

CPRSChart.exe

If CPRS executable name is CPRSChart.exe, add the following four (4) lines at the bottom of the file:

[CPRSChart]
App Support GUID={dd100104-6205-11cf-ae61-0000e8a28647}
[CPRSChart\Enable Class Names]
TRichEdit=4 

 

To learn more and to keep current with any changes to this topic, log in to iSupport and click the solution links below:

16784: Resolve Jumping Cursor within CPRS


 

   back to top

 


Recommended iSupport KBs


Link up with Information Fast!

The following iSupport solutions (knowledge base articles) are recommended for the VA.

iSupport users can add specific solutions to the Quick Links section on their iSupport Dashboard.

Note NOTE: Viewing linked iSupport solutions below require logging into iSupport.


14111 - DMNE Product Documentation

15981 - Anti-Virus recommendations for Dragon Medical

16821 - DFS Replication problems cause performance issues and profile corruption

16879 - Microsoft CEIP causes client issues with performance, crashing, and hanging

16449 - Webinar Series (registration and video archive)

Device Hardware Compatibility List

 

   back to top

 

Thank you for partnering with Nuance!